Files
Kevin BowlingandEric Joyner 41418a7cd0 ifconfig: Add SR-IOV VF status output
Add NIC-specific VF status to the existing ifconfig -v output.  Fetch
the data through libifconfig using a separate native route Netlink
query.

Group optional identity, initialization, resources, VLAN policy,
administrator policy, protocol, traffic-permission, and
fault containment fields.  Omitted fields remain distinct from false or
zero.

Refer users to iovctl -L for device-neutral PCI attachment and
passthrough state.

This is a Netlink-native evolution of the original interface by Eric
Joyner.

Relnotes:	yes
Sponsored by:	Intel Corporation (initial version)
Sponsored by:	BBOX.io
Differential Revision:	https://reviews.freebsd.org/D58778

Co-authored-by: Eric Joyner <[email protected]>
2026-09-06 06:51:53 -07:00

149 lines
4.3 KiB
Plaintext

.\"
.\" Copyright (c) 2014 Sandvine Inc.
.\" All rights reserved.
.\"
.\" Redistribution and use in source and binary forms, with or without
.\" modification, are permitted provided that the following conditions
.\" are met:
.\" 1. Redistributions of source code must retain the above copyright
.\" notice, this list of conditions and the following disclaimer.
.\" 2. Redistributions in binary form must reproduce the above copyright
.\" notice, this list of conditions and the following disclaimer in the
.\" documentation and/or other materials provided with the distribution.
.\"
.\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
.\" ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
.\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
.\" SUCH DAMAGE.
.\"
.Dd August 10, 2026
.Dt IOVCTL 8
.Os
.Sh NAME
.Nm iovctl
.Nd "PCI SR-IOV configuration utility"
.Sh SYNOPSIS
.Nm
.Fl C
.Fl f Ar config-file
.Op Fl n
.Nm
.Fl D
.Op Fl f Ar config-file | Fl d Ar device
.Op Fl n
.Nm
.Fl L
.Op Fl f Ar config-file | Fl d Ar device
.Nm
.Fl S
.Op Fl f Ar config-file | Fl d Ar device
.Sh DESCRIPTION
The
.Nm
utility configures and inspects PCI Single-Root I/O Virtualization
.Pq SR-IOV
Virtual Functions
.Pq VFs .
When invoked with the
.Fl C
flag,
.Nm
creates VFs as children of the Physical Function
.Pq PF
configured in the specified configuration file.
When invoked with the
.Fl D
flag,
.Nm
destroys all VFs that are children of the specified device.
Available PF devices can be seen in
.Pa /dev/iov/ .
.Pp
The following options are available:
.Bl -tag -width indent
.It Fl C
Enable SR-IOV on the specified PF device and create VF children.
This operation will fail if the PF already has VF children.
This option must be used in conjunction with the
.Fl f
option.
.It Fl d Ar device
Specify the PF device to use for the given operation.
.Ar device
may either be the name of a PF device, or a full path name to a node in
.Pa /dev/iov/ .
This option may not be used with the
.Fl C
option.
.It Fl D
Delete all VF children of the specified PF device.
This operation will fail if SR-IOV is not currently enabled on the specified
device.
.It Fl f Ar config-file
Specify the pathname of the configuration file.
For the
.Fl C
option, this file will be used to specify all configuration values.
For the
.Fl D ,
.Fl L ,
and
.Fl S
options, this file will only be used to specify the name of the PF device.
.Pp
See
.Xr iovctl.conf 5
for a description of the config file format and documentation of the
configuration parameters that apply to all PF drivers.
See the PF driver manual page for configuration parameters specific to
particular hardware.
.It Fl n
Perform a dry-run.
Perform all validation of the specified action and print what would be done,
but do not perform the actual creation or destruction of VFs.
This option may not be used with the
.Fl L
or
.Fl S
flag.
.It Fl L
Report the current PCI SR-IOV topology of the specified PF.
The output identifies the PF and each configured VF by PCI location, reports
whether each VF is attached to a host driver, and identifies bindings to
.Va ppt .
An unconfigured PF reports its enable state and VF capacity without any
per-VF records.
A passthrough binding does not imply that a running virtual machine currently
owns the VF.
See
.Xr vmm 4
for passthrough-device configuration.
.It Fl S
Read the configuration schema from the specified device and print its contents
to stdout.
This action may be used to discover the configuration parameters supported on
a given PF device.
.El
.Pp
For network devices, use
.Xr ifconfig 8
with the
.Fl v
option on the PF interface to display NIC-specific VF initialization,
resource, and policy state.
.Sh SEE ALSO
.Xr vmm 4 ,
.Xr iovctl.conf 5 ,
.Xr rc.conf 5 ,
.Xr ifconfig 8
.Sh AUTHORS
This manual page was written by
.An Ryan Stone Aq Mt [email protected] .