mirror of
git://git.kernel.org/pub/scm/linux/kernel/git/xiang/erofs.git
synced 2026-11-10 19:39:54 +01:00
The probe does not strictly require the USB_CDC_DMM_TYPE descriptor, which is a good thing as it makes the driver usable on non-conforming interfaces. A user could e.g. bind to it to a CDC ECM interface by using the new_id and bind sysfs files. But this would fail with a 0 buffer length due to the missing descriptor. Fix by defining a reasonable fallback size: The minimum device receive buffer size required by the CDC WMC standard, revision 1.1 Signed-off-by: Bjørn Mork <[email protected]> Cc: stable <[email protected]> Signed-off-by: Greg Kroah-Hartman <[email protected]>