Files
Wadim Mueller 22bba9dfd2 iio: types: add IIO_VOLUMEFLOW channel type
Add a new IIO channel type for liquid volumetric flow sensors.  The
unit exposed via the standard _scale attribute is cubic metres per
second (m^3/s), following the SI convention used by the other IIO
channel types.

Update iio-core's name table, the iio_event_monitor whitelist and
the sysfs-bus-iio ABI document to match.  The new _scale attribute is
folded into the existing shared _scale block; only the per-type _raw
needs a fresh entry.

Signed-off-by: Wadim Mueller <[email protected]>
Reviewed-by: Joshua Crofts <[email protected]>
Signed-off-by: Jonathan Cameron <[email protected]>
2026-08-05 00:02:55 +01:00
..
2024-09-05 19:27:13 +01:00