perf python: Add support to resolve tracepoint fields

Adding tp_getattro callback for sample event. It resolves tracepoint
fields in runtime.

It's now possible to access tracepoint fields in normal fashion like
hardcoded ones (see the example in the next patch).

Reported-and-Tested-by: Jiri Pirko <[email protected]>
Signed-off-by: Jiri Olsa <[email protected]>
Cc: David Ahern <[email protected]>
Cc: Namhyung Kim <[email protected]>
Cc: Peter Zijlstra <[email protected]>
Link: http://lkml.kernel.org/r/[email protected]
Signed-off-by: Arnaldo Carvalho de Melo <[email protected]>
This commit is contained in:
Jiri Olsa authored and Arnaldo Carvalho de Melo committed 2016-07-12 16:19:16 -03:00
1 parent 377f698db1
commit bae57e3825
1 file changed
+92
+92
View File
@@ -290,6 +290,97 @@ static PyObject *pyrf_sample_event__repr(struct pyrf_event *pevent)
return ret;
}
static bool is_tracepoint(struct pyrf_event *pevent)
{
return pevent->evsel->attr.type == PERF_TYPE_TRACEPOINT;
}
static int is_printable_array(char *p, unsigned int len)
{
unsigned int i;
for (i = 0; i < len; i++) {
if (!isprint(p[i]) && !isspace(p[i]))
return 0;
}
return 1;
}
static PyObject*
tracepoint_field(struct pyrf_event *pe, struct format_field *field)
{
struct pevent *pevent = field->event->pevent;
void *data = pe->sample.raw_data;
PyObject *ret = NULL;
unsigned long long val;
unsigned int offset, len;
if (field->flags & FIELD_IS_ARRAY) {
offset = field->offset;
len = field->size;
if (field->flags & FIELD_IS_DYNAMIC) {
val = pevent_read_number(pevent, data + offset, len);
offset = val;
len = offset >> 16;
offset &= 0xffff;
}
if (field->flags & FIELD_IS_STRING &&
is_printable_array(data + offset, len)) {
ret = PyString_FromString((char *)data + offset);
} else {
ret = PyByteArray_FromStringAndSize((const char *) data + offset, len);
field->flags &= ~FIELD_IS_STRING;
}
} else {
val = pevent_read_number(pevent, data + field->offset,
field->size);
if (field->flags & FIELD_IS_POINTER)
ret = PyLong_FromUnsignedLong((unsigned long) val);
else if (field->flags & FIELD_IS_SIGNED)
ret = PyLong_FromLong((long) val);
else
ret = PyLong_FromUnsignedLong((unsigned long) val);
}
return ret;
}
static PyObject*
get_tracepoint_field(struct pyrf_event *pevent, PyObject *attr_name)
{
const char *str = PyString_AsString(PyObject_Str(attr_name));
struct perf_evsel *evsel = pevent->evsel;
struct format_field *field;
if (!evsel->tp_format) {
struct event_format *tp_format;
tp_format = trace_event__tp_format_id(evsel->attr.config);
if (!tp_format)
return NULL;
evsel->tp_format = tp_format;
}
field = pevent_find_any_field(evsel->tp_format, str);
if (!field)
return NULL;
return tracepoint_field(pevent, field);
}
static PyObject*
pyrf_sample_event__getattro(struct pyrf_event *pevent, PyObject *attr_name)
{
PyObject *obj = NULL;
if (is_tracepoint(pevent))
obj = get_tracepoint_field(pevent, attr_name);
return obj ?: PyObject_GenericGetAttr((PyObject *) pevent, attr_name);
}
static PyTypeObject pyrf_sample_event__type = {
PyVarObject_HEAD_INIT(NULL, 0)
.tp_name = "perf.sample_event",
@@ -298,6 +389,7 @@ static PyTypeObject pyrf_sample_event__type = {
.tp_doc = pyrf_sample_event__doc,
.tp_members = pyrf_sample_event__members,
.tp_repr = (reprfunc)pyrf_sample_event__repr,
.tp_getattro = (getattrofunc) pyrf_sample_event__getattro,
};
static char pyrf_context_switch_event__doc[] = PyDoc_STR("perf context_switch event object.");